[HTML][HTML] Intraocular pressure measurement with pneumatonometry and a tonometer tip cover

TJ Ferguson, CG Knier, UR Chowdhury… - Ophthalmology and …, 2020 - Springer
… 30 pneumatonometer through the Tono-Pen tip cover compared with pneumatonometry
measurements without a Tono-Pen cover … the presence of bias with the Tono-Pen cover in place. …

[HTML][HTML] Comparison of the iCare, Tono-Pen, non-contact airpuff, and Goldmann applanation tonometers in eyes with corneal edema after penetrating keratoplasty

SJ Yeh, KH Chen, TM Kuang, CJL Liu… - Journal of the Chinese …, 2021 - journals.lww.com
… , NCT was more affected by corneal thickness (0.4-0.63 mmHg/… The Tono-Pen is a handheld
tonometer used to measure IOP … , and intraocular pressure level on Goldmann applanation

… Association of Central Corneal Thickness and Intraocular Pressure Measures by Non-Contact Tonometry and Goldmann Applanation Tonometry among Glaucoma …

S Kyei, F Assiamah, MA Kwarteng… - Ethiopian Journal of Health …, 2020 - ajol.info
Corneal Thickness (CCT) is associated with intraocular pressure measurement (IOP) with
a Non-contact tonometer and the … Goldmann, pneumotonometer and noncontact tonometer

[HTML][HTML] Assessment of intraocular pressure measurement between Goldman applanation tonometer, rebound tonometer, non-contact tonometer, and its correlation …

AC Porwal, M Shrishrimal, RP Punamia… - Indian Journal of …, 2023 - journals.lww.com
corneas underestimate IOP values, whereas thicker corneas overestimate them. [ 6 ] Keeping
this in mind, we wanted to compare the IOP readings … with central corneal thickness (CCT) …

[HTML][HTML] Compare and study intraocular pressure measured by noncontact tonometer and contact tonometer (Goldmann's applanation tonometer and schiotz) and …

S Lohiya, R Pardasani - Journal of Datta Meghe Institute of …, 2020 - journals.lww.com
… was found to read slightly higher reading than Goldmann's applanation tonometer. This
study observed that overall IOP as measured by NCT was significantly higher than GAT (P = …

[PDF][PDF] The effects of corneal edema on the intraocular pressure measurements

E Seven, S Tekin, M Batur, B Yavuzer… - Eastern Journal of …, 2020 - jag.journalagent.com
measurements with the pneumotonometer, GoldmannEffect of central corneal thickness
and radius of the corneal curvature on intraocular pressure measured with the Tono-Pen and …

Corrected intraocular pressure variability with central corneal thickness measurement

MAA Ahmed, AS Abdelhalim - Clinical Ophthalmology, 2020 - Taylor & Francis
… central corneal thickness could affect the GAT-measured IOP values. However, corrected-IOP
values … comparing the ultrasonic or optical methods used for CCT measurement. The GAT-…

[HTML][HTML] Intraocular Pressure Measurements with Pneumotonometer and Tono-Pen in Patients Using Topical Antiglaucomatous Medication Due to Primary Open …

K Özülken, Ç İlhan - Acıbadem Üniversitesi Sağlık Bilimleri …, 2020 - journal.acibadem.edu.tr
… The IOP measurements obtained with pneumotonometer and Tono-Pen were statistically
compared with the IOP measurements obtained with GAT, and the correlations between series …

[HTML][HTML] International comparisons of intraocular pressures, as measured by Tono-Pen and Goldmann applanation tonometry, in healthy adults: A meta-analysis

WJ Keller - Medicine, 2023 - journals.lww.com
… , for example, central cornea thickness, diurnal variations in IOP, patient’s … measurement
of IOP to be made with the Tono-Pen XL (TP) or Tono-Pen AVIA (TP) applanation tonometers

The effect of central corneal thickness on intraocular pressure measurement in a sample of Iraqi patients with an age range between 30-60 years old

NMA Haleem, SS Abdullah, MH Ahmed - AIP Conference Proceedings, 2023 - pubs.aip.org
… blood flow (OBF) pneumotonometer were noticeably higher than the reading obtained by
the Goldmann applanation tonometer or TonoPen in patients who have different …